Sichuan Rongteng Automation Equipment Co., Ltd.

We are focus on CNG and natural gas industries . From natural gas processing to CNG station. Provide best solutions for the customers. EPC serivce is available.

Manufacturer from China
Active Member
7 Years
Home / Products / Natural Gas Dehydration /

High Pressure Natural Gas Dehydration Equipment With Dual Drainage Valves

Contact Now
Sichuan Rongteng Automation Equipment Co., Ltd.
Province/State:sichuan
Country/Region:china
Contact Person:MrArnold Shao
Contact Now

High Pressure Natural Gas Dehydration Equipment With Dual Drainage Valves

Ask Latest Price
Brand Name :SCRT
Model Number :RT-TS150
Certification :ISO
Place of Origin :China
MOQ :1 set
Price :negotiable
Supply Ability :100 per month
Delivery Time :30 days
Packaging Details :Wooden box
Application :natural gas
Warranty :18 month
Product name :natural dehydration equipment
after sales services :Engineers available to service machinery overseas
Configuration :stationary, portable
Dimension :customized
Color :customized
Medium :Natural gas
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

High pressure natural gas dehydration equipment for natural gas dewatering

Description:

The high pressure natural gas dehydration equipment refers to the equipment installed in the compressor after the original Department of pneumatic up to 25 MP products.

Based on the principle of variable temperature adsorption and dehydration, the saturated water in raw natural gas is adsorbed under high pressure by the physical properties of adsorbent, and then the saturated adsorbent is analyzed by dry gas under low pressure at high temperature.

Adsorption and analysis are carried out in reverse fashion.

Features:

The natural gas dehydration equipment has the below feaures.

1. The main valve of the process adopts the imported needle valve, the exhaust outlet is equipped with pressure butter valve, and the regeneration switching is equipped with air balance pipeline system, so that the air flow can be balanced and the service life of adsorbent can be protected from multiple angles.

(2) Dual drainage valves are used to ensure reliable drainage and no leakage.

(3) Adopt anti-icing plugging pressure regulation design to make the regeneration air flow more smoothly.

Technical parameters:

1 Power of regenerative heater (KW/V) 12-18/380
2 The rated flow (Nm3/h) 1500, 4000,
3 Heater design temperature ( °C ) 350
4 Adsorption design pressure (Mpa) 27.5
5 Inlet temperature (°C) ≤45
6 Regenerative design pressure (Mpa) 3.5
7 Inlet oil content (mg/Nm3) ≤5
8 Finished product dew point ( °C) ≤-60
9 Dust content of finshed gas Mg /Nm3 ≤5
10 Dust diamter of finished gas μm ≤3
11 Way to work The two towers work alternately
12 Regenerative gas extraction method High pressure gas extraction decompression regeneration
13 Cooling way Air cooled or water cooled *
14 Mode of operation Manual or automatic
15 Overall dimensions (m) 1.85X1.39X3.19 or 2.25X1.5X2.62
16 Weight (kg) 2600-3000

High Pressure Natural Gas Dehydration Equipment With Dual Drainage Valves