Add to Cart
Sewage treatment equipment for natural gas pipeline pressure test
Description:
The Sewage treatment equipment purify the waste water from the natural gas pipeline pressure test.
Technical parameters:
1 | Processing capacity | 100-500 m3/h |
2 | Inlet Pump Pressure | <80m (Head of delivery) |
3 | Medium inlet and outlet temperature | room temperature |
4 | Design Pressure | > 1.6 Mpa |
5 | Design temperature | 0 ~+80℃ |
6 | Filtration accuracy | <10 um |
7 | PH value | 6-9 |
8 | Chromaticity | <80 |
9 | Suspended solids (mg/L) | <150 |
10 | Quality indicators achieved by the product: The discharged water reaches the second level of the Comprehensive Wastewater Discharge Standard (GB8978-1996). |