Add to Cart
MRC type 5X104 Nm3/d Mini LNG plant LNG liquefaction plant for nautral gas LNG plant skid
Technical features:
1. Low energy consumption for liquefaction, and low energy consumption mixed coolant refrigeration process (MRC) is preferred;
2. The process is mature and reliable, the process organization is advanced, and the operation and maintenance is simple. Only 3 operators are needed in one shift, and the start-up time is fast, and the time from start-up to product production is less than 3 hours;
3. High degree of integration. All of them are skid mounted, with small number of skids and small floor area.
4. Independent mechanical and electrical connection technology is adopted for the connection between skids, which is convenient and fast for installation, without welding on site, with good mobility and short installation period (20-50 days). Advanced system configuration, complete functions, priority to reliability, and reliable products are used for pipe fittings.
5. With remote diagnosis function, the response to user fault can be reduced to 1 hour through remote real-time data transmission;
6. The control cabin is adopted. The instrument and electric control cabinets are all placed in the cabin. The air conditioner is equipped in the cabin to meet the use requirements of electronic components. It is explosion-proof and easy to move.
7. DCS control technology and TCP / IP communication protocol are adopted. Compared with modbus, TCP / IP communication protocol has the advantages of wide utilization range, long communication distance and high speed.
Main parameter
Product model | MB-LNG | MB-LNG | MB-LNG 1250 | MB-LNG 2084 | MB-LNG 4167 |
Processing capacity | 1X104 Nm3/d | 2X104 Nm3/d | 3X104 Nm3/d | 5X104 Nm3/d | 10X104 Nm3/d |
Flexibility of device operation | 50%-110% | ||||
Liquefied rate | 100% | ||||
Process method | Mixed refrigerant cycle (MRC) | ||||
Energy consumption of refrigeration | ≤0.32 Kwh/Nm3 LNG | ||||
Inlet pressure | 0.2 MPa.g | ||||
LNG product parameters | Storage pressure: 0.3 MPa.G; Temperature: -162℃ | ||||
Explosion-proof grade | Exia II CT4 | ||||
Area covered | ~3400m2 | ~4700m2 |